8.1 Input Info
Input Info
Input Selection
This control selects the input to be displayed among the available ones.
Input Description
Description of the input as described in the Input Setup.
Input Statistics
This indicator displays the standard statistics of the input measurement. The
whole file length is considered no matter the length displayed on the graphs.
The Unit refers to the Unit Name set in the Input Setup.
rms: The AC component of the signal in Unit rms.
Mean: The DC component of the signal in Unit.
Min: The minimum level of the signal in Unit.
Max: .The maximum level of the signal in Unit.
Crest Factor: The peak-to-average ratio.