Soft-db Opus Suite Data Logger Module Manuale Utente Pagina 46

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 62
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 45
45
The parameters are described in the following table:
Integration Parameters
Description
A simple or double operation can be done. A first (simple integration)
or second order (double integration) filter is used following this
parameter.
This is the cut-off frequency for the filter used in the integration
process. We suggest using an Fcut(Hz) parameter that fits with the
sensor used. A typical accelerometer sensor has a flat frequency
response that starts at around 20 Hz.
This control allows selecting the group of channels for which the integration will be done.
This button launches the integration operation.
Vedere la pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 61 62

Commenti su questo manuale

Nessun commento